
Paper-insulated lead-covered · city duct cable
PILC cable buyers in New York
Paper-insulated lead-covered cable is the oldest cable construction still coming out of New York buildings and duct systems in quantity, and it is the one most often destroyed by the way it is removed.
- New York State
- Documented lots
- Reels and cut lengths
- Buyer review
Sell this cable
Send the construction, size and footage. Photographs can follow.
Prefer to talk? 614-715-3047 · saleselectricalbuyers@gmail.com
PILC is copper conductor, oil-impregnated paper insulation and a lead sheath, often with steel tape armour and a jute serving over it. Value comes from two metals, not one: the copper conductor and the lead sheath both have recovery value, and the construction decides which is worth more. Three-conductor belted cable and three-conductor shielded cable are different products, and a wiped joint or splice casing can double the metal in a length.
What PILC is, layer by layer
PILC is a laminated dielectric cable. The conductor is stranded copper, sometimes tinned, and over it are many thin paper tapes applied in layers and impregnated under vacuum with a mineral oil or synthetic impregnant. A lead sheath is extruded over the insulation to keep moisture out and impregnant in, then comes a bedding layer, steel tape or wire armour where mechanical protection is needed, and an outer serving of jute or bitumen-impregnated tape.
The construction has two variants that matter commercially. In three-conductor belted cable, three insulated cores are laid up with paper fillers and a common lead sheath, and the insulation relies on the belt papers over the whole core assembly rather than on individual metallic screens. In three-conductor shielded cable, each core carries its own metallic shielding tape over the insulation, which gives a radial stress control and a different fault behavior. Single-conductor PILC is used for larger feeders and for oil-filled designs at higher voltages.
Oil-filled cable is the third case. The conductor is hollow or has an oil channel, and the cable is connected to reservoirs that keep the impregnant under pressure, so the insulation stays filled as load cycles expand and contract it. Those runs come with pressure tanks, gauges and oil records, and they are valued quite differently from solid-type cable.

Why New York still has so much of it
The city's distribution system was built in duct, and PILC was the standard cable for duct work for most of the twentieth century. Concrete duct banks run under the streets between manholes, and the cable inside them has to survive occasional water, so a hermetic lead sheath was the right answer for a very long time. Much of that cable is still in service, which is why removals keep producing it.
The voltage classes you see are the classes the city uses: 5 kV and 4 kV legacy network work, 15 kV class feeders, 27 kV and 35 kV where the system was upgraded. A three-conductor 15 kV belted length is the bread-and-butter item; a single-conductor 27 kV shielded length is a different and heavier proposition.
Identifying it at a cut end
A cut end tells you almost everything, and it takes less than a minute. Score the outer serving and peel it back: jute or bitumen tape over steel tape armour is the classic build. Under the armour is bedding, and under that the lead. Lead is soft, gray, and dents with a thumbnail; it cuts with a knife and does not spring back the way copper does. Cut the lead back and the paper is unmistakable — thin crepe tapes wound in layers, usually pale yellow to brown, that unwind when you pick at them, with a smell of mineral oil.
The conductor is the last layer: stranded copper, bright if it has been protected, dark green if moisture has been at it. Tinned strands on older cable are normal and not a defect. If there is a hollow core or a channel in the conductor, the cable is oil-filled rather than solid-type, and that changes both the value and the handling.
| What you see | What it tells you |
|---|---|
| Jute or bitumen outer serving over steel tape | Armoured, direct-buried or duct cable, not riser cable |
| Soft gray sheath that dents with a thumbnail | Lead sheath, the moisture barrier and a second metal value |
| Thin tapes that unwind from the insulation | Impregnated paper, which confirms the family |
| Three insulated cores inside one sheath | Three-conductor construction, belted or shielded |
| Thin copper tapes over each core | Shielded three-conductor, not belted |
| Hollow or channelled conductor | Oil-filled design with reservoirs and oil records |
Wiped joints, splices and why the joints matter
PILC is joined by hand. The lead sheath is opened, the conductors are spliced, the insulation is rebuilt with paper or a premoulded joint body, and the whole thing is re-sheathed with a lead sleeve that is wiped into the original sheath with solder. A wiped joint is a skilled, slow, disappearing trade, and the wipes are also where most of the lead in a removed run sits.
For a seller this matters in two ways. A run that comes out with its joints intact is heavier and carries more lead than a clean length, and a joint casing is a solid piece of lead rather than a thin sheath. And a length that was cut at every joint is shorter and less useful than one that came out whole, though at distribution class most of it was cut at the manholes anyway.
Lead, oil and handling
Two materials make PILC a different kind of job from extruded cable. Lead is toxic, and handling it produces dust and, if it is cut with a power tool or heated, fume. Removal is done by the owner's qualified personnel on de-energised, released circuits, with the lead handled as a hazardous material under the owner's procedures and applicable federal and state rules; it is not something to burn, grind or sweep up casually. The impregnant is an oil, so cut cable drains, and older fluid should be tested rather than assumed clean, because some legacy dielectric fluids contain PCBs.
None of that makes the cable worthless — lead and copper are both recovery metals with established routes — but it does mean a lot should be described honestly, stored on a containment surface rather than on bare ground, and moved by people who know what is in it. This page describes handling, not compliance; the owner's environmental and safety procedures govern the job.
- De-energise and release through the owner's switching procedure before any removal
- Cut and coil on containment, not on soil, and keep the ends from draining into a yard
- Treat lead as a hazardous material in handling, storage and transport
- Test older impregnant before assuming it is clean
- Describe the construction and approximate copper and lead content in the enquiry
Specification
What a buyer needs to know about this cable
Every row below changes what a lot is worth. If the reel tag is gone, the jacket print and a cut end usually answer most of it.
Missing detail is not a problem — say what is missing and the review works from photographs.
| Construction | Copper conductor, impregnated paper insulation, lead sheath, bedding, armour and outer serving |
|---|---|
| Conductor | Stranded copper, typically 1/0 AWG through 1,000 kcmil; three-conductor and single-conductor forms |
| Voltage classes | 5 kV through 35 kV; 15 kV and 27 kV dominate New York City duct work |
| Insulation | Oil-impregnated paper tapes; solid-type, non-draining, or oil-filled with a central oil channel |
| Sheath | Extruded lead or lead alloy, wiped at joints and terminations |
| Standards | AEIC CS6 for impregnated paper-insulated lead-covered cable |
| Armour | Steel tape or wire armour over bedding, with jute or bitumen serving outside |
| Hazards | Lead dust and fume, mineral oil impregnant, oil-soaked duct water |
Constructions
PILC lots we review
The construction and the voltage class decide which metals dominate the value.
Three-conductor belted, 5 kV class
The oldest and most common city construction: three paper cores under one lead sheath, heavy in lead per foot of copper.
Three-conductor shielded, 15 kV class
Individual core shielding under a common sheath, used on the feeders that carry most of the city's distribution load.
Single-conductor 27 kV and 35 kV
Heavier insulation, larger copper and a sheath that is a meaningful fraction of the metal in the run.
Oil-filled PILC
Hollow-core cable with reservoirs and pressure equipment, from transmission-class paper systems. Oil records decide the handling plan.
Joints, splices and potheads
Wiped lead sleeves, splice casings and terminal housings. Dense in lead, and worth separating from the cable.
Mixed duct pulls
Manhole-length pieces from several circuits, often with different classes and ages. Sorted by class, it is worth more than as one coil.
New York
PILC in the New York market
Paper cable comes out of the ground in the city continuously, circuit by circuit, as duct systems are rebuilt and network feeders replaced. Each removal produces short lengths between manholes, a set of wiped joints, and a quantity of lead that is easy to underestimate until it is weighed. Because the material is heavy and the handling rules are strict, it is often sold quickly and cheaply to whoever will take it away.
That is where value is lost. A lot described as mixed paper cable with no class, no construction and no weights is a disposal job. The same lot sorted into belted and shielded, with the joints and potheads separated and the copper and lead estimated, is a metals transaction with a known basis.
What helps a New York lot move
- Voltage class and construction stated for each coil or drum
- Belted versus shielded identified, not left as paper cable
- Joints, splice casings and potheads kept separate from straight lengths
- Approximate copper and lead content, or the weights before and after stripping a sample
- Confirmation that the cable is de-energised and released, and how it was stored

Seller questions
Questions sellers ask
How do I know a cable is PILC and not XLPE?
Cut back the outer layers. PILC has a soft lead sheath that dents with a thumbnail and paper tapes that unwind underneath; XLPE has a solid extruded wall that shaves cleanly and springs back, with no lead. The weight is also different, because lead is far denser than any plastic sheath.
Is the lead sheath actually worth anything?
Yes. Lead is a recovery metal with an established recycling route, and on small-conductor cable the sheath can be a large share of the total metal. That is also why handling matters: lead is toxic, and cutting, grinding or heating it creates dust and fume that has to be controlled under the owner's procedures.
Can old PILC cable be reused rather than scrapped?
Occasionally, for a like-for-like repair where an owner still maintains paper cable and has the splicers to joint it. In most cases the answer is no: the insulation takes on moisture as soon as the sheath is opened, and the lengths removed from duct are short. Assume recovery value unless an owner specifically wants the construction.
What voltage classes of PILC come out of New York buildings?
Service and distribution classes, mainly 5 kV and 15 kV, with 27 kV and 35 kV on heavier feeders and legacy network work. Buildings with old switchgear often hold short three-conductor runs at 5 kV or 15 kV, frequently with the potheads still attached.
Why is the copper sometimes tinned?
Tinning was standard practice on older paper cable to protect the strands from sulphur in the impregnant and from corrosion at joints. It does not reduce the copper value, and it is a useful sign that the cable predates the plastics era.
Keep reading
Related pages
- HPFF cable buyersThe pressurised pipe-type cousin of paper cable
- High-voltage cable buyersThe parent category for cable work
- 69 kV cable buyersShielded subtransmission cable, extruded and paper
- Decommissioned substation cable buyersStation clearances that release paper cable
- Substation wire and bus buyersBus, jumpers and control wiring
- Transmission line cable buyersOverhead material for contrast
City pages
Where this turns up in New York
Next step
Send the lot details
Include the storage city, how it is stored and what can reach it. If you have photographs of reel tags or jacket print, send them with the enquiry.
Send the lot
One desk reviews every lot that arrives.
Prefer to talk? 614-715-3047 · saleselectricalbuyers@gmail.com