Surplus electrical wire & cable buyers · New York State

Direct buyer review · no fee to submit a lot

Call or text 614-715-3047

saleselectricalbuyers@gmail.com

New York Wire Buyers Surplus wire & cable desk
Large cable reels stored outdoors in a utility yard beside a low industrial building

Transmission · bulk overhead and city pipe-type

345 kV cable buyers in New York

345 kV is the top of New York's alternating-current transmission in normal service, and it produces the two most mispriced lots in the state: bundled overhead conductor sold by weight, and city pipe-type cable sold as heavy scrap.

  • New York State
  • Documented lots
  • Reels and cut lengths
  • Buyer review

Sell this cable

Send the construction, size and footage. Photographs can follow.

No fee and no obligation. Nothing is bought, moved or scheduled until written lot terms are agreed.

Prefer to talk? 614-715-3047 · saleselectricalbuyers@gmail.com

Quick answer

There is no single 345 kV lot. Overhead, it is two-conductor bundle in 795 or 954 kcmil with spacers, armour rods and an optical shield wire, and tagged drums of it can go back on a line. Underground in New York City it is high-pressure fluid-filled pipe cable, where the copper and the steel pipe carry the value and the fluid is a cost. Both are routinely undervalued, for the same reason: the paperwork that proves what they are gets separated from the material.

Two lots that share a voltage and nothing else

New York's 345 kV system is the bulk network: the lines that move power from the Niagara and St. Lawrence hydro stations, from the north country and from the Quebec and PJM interconnections toward the load in the southeast of the state. Almost all of it is overhead. In New York City, the 345 kV connections that feed the distribution network are underground and they are pipe-type, because at this voltage and this density there has never been a realistic alternative.

So the same voltage label sits on a drum of aluminum wire and on a welded steel pipe. One is bought by line contractors who care about code name and footage. The other is bought by recovery operations that care about copper content and the cost of moving oil. Treating them as one category is how sellers end up accepting a scrap number for material that had a second life in it.

Large cable reels stored outdoors in a utility yard beside a low industrial building

Overhead 345 kV: the bundle and everything above it

A 345 kV phase is normally two sub-conductors rather than one. The pair is spaced by bundle spacers at intervals along the span, held at the structure by suspension assemblies with armour rods, and tensioned by pullers and tensioners so the conductor never touches the ground during stringing. That method is why removed 345 kV conductor is usually straight and why new surplus usually has factory-sealed ends and a clean tag — and equally why conductor that was dropped or dragged is obvious to a buyer.

The conductor sizes are the familiar ones: 954 kcmil Cardinal in 54/7, 795 kcmil Drake in 26/7, and 1,272 kcmil Bittern in 45/7 where a river or valley crossing demands it. Where a line has been uprated, ACSS or a high-temperature construction may have replaced the original ACSR on the same structures, and drums from that work are worth more than the same weight of older conductor.

Above the phases sits the shield wire, increasingly OPGW with 24 to 48 fibers and a splice at every tension structure. A 345 kV rebuild produces all of this at once, and the lot is only as good as the seller's willingness to keep it sorted.

  • Code name and stranding per drum, with footage from the tag
  • Spacers, dampers and armour rods counted as sets rather than weighed
  • OPGW fiber count and reel length, with sealed ends
  • Insulator strings by material and condition
  • New surplus kept apart from removed conductor

City 345 kV: high-pressure fluid-filled pipe

A high-pressure fluid-filled circuit is a cable inside a pipeline. The cable is paper-insulated copper, taped and vacuum-impregnated, with a large segmental or compact conductor; the pipe is welded steel, coated on the outside and protected cathodically; and the void between cable and pipe is filled with degassed dielectric fluid held under pressure by a pumping plant. Potheads at each end bring the conductor out through a sealed housing, and pressure and flow monitoring is part of the protection scheme, because a sudden loss of fluid is a fault signature.

That construction is why retirement is planned rather than incidental. The fluid has to be drained and handled, the pipe has to be cut and lifted, the cable has to be pulled, and the terminal equipment has to be either preserved as spares or dismantled. It is also why the material is so often sold cheaply: the seller sees a heavy, wet, awkward object with a disposal cost attached, and the buyer sees a large quantity of copper, several tons of steel pipe and a set of terminal hardware that somebody with the same design will want.

Why 345 kV is the most commonly undervalued material in the yard

Three things push it down. First, weight: a 345 kV reel or a pipe section is heavy, and heavy material attracts weight-based offers, which is the wrong measure for a product defined by footage and construction. Second, documentation: the tag, the test record and the oil history are usually in a file that gets closed when the project does, and material separated from its paperwork loses most of its premium. Third, handling: few buyers can move a large steel reel or a pipe section, so the seller's choice is narrow and the price reflects it.

The counter-argument is straightforward. A tagged drum of 954 kcmil conductor is a line-store item that a contractor will pay material money for, and a retired pipe-type circuit contains copper at a scale that no other cable class in the state matches. Neither should be sold on a bathroom scale, and neither should be sold before the documents have been looked for.

The documents that actually change the number

For overhead material, the reel tag is the asset. It gives the construction, the code name, the length and often the purchase order, and it converts a drum of wire into a specific product. Running footage or sequential length marking on the conductor itself is the next best thing, because it lets a buyer calculate what is left after a partial pull without trusting a hand-written note.

For pipe-type cable, the paperwork is different and heavier. Fluid type and volume, the results of fluid tests, the pressure history, the as-built route drawings and the factory test records together describe a system rather than a length of cable. Factory routine tests on this class of cable include partial discharge and AC withstand measurements, and field commissioning tests were run after installation; both are worth having, and their absence is not fatal but it does move the material toward recovery value.

DocumentWhat it settlesWithout it
Drum tagConstruction, code name, length, purchase orderIdentification by legend and measurement only
Running footage or sequential markingWhat remains after a partial pullLength estimated from wrap diameter
Factory test recordRoutine partial discharge and AC withstand resultsCondition assumed, not shown
Fluid test historyFluid type, moisture and dielectric strengthSampling required before any quote
As-built route drawingsPipe size, length, joints and terminal arrangementRun measured on site

Specification

What a buyer needs to know about this cable

Every row below changes what a lot is worth. If the reel tag is gone, the jacket print and a cut end usually answer most of it.

Missing detail is not a problem — say what is missing and the review works from photographs.

Specification checklist
Voltage class345 kV three-phase transmission, 199 kV to ground
Overhead conductorACSR or ACSS, usually two sub-conductors per phase at 795 or 954 kcmil; 1,272 kcmil on long crossings
Line hardwareBundle spacers, armour rods, suspension and dead-end assemblies, dampers, insulator strings
Pipe-type cablePaper-insulated copper conductor, segmental or compact strand, inside welded steel pipe
Pipe and fluidNominal 5 to 8 in coated steel pipe, dielectric fluid under pressure, cathodic protection
TerminationsPotheads and apparatus housings at each end, with a pumping plant maintaining pressure
StandardsASTM B232 and B856 for conductor, AEIC CS2 for pipe-type cable, ICEA S-108-720 for extruded work
DocumentsDrum tag, running footage, oil history, factory and field test records, as-built drawings

Constructions

345 kV lots we review

Bulk transmission material arrives either on a reel or in a pipe, and the two are handled differently.

01

Bundled line conductor

Two sub-conductors per phase from a reconductor or rebuild, on tagged drums or in long removed pulls.

02

OPGW and shield wire

Optical ground wire from the same structures, with fiber count and reel length, or conventional static wire.

03

Line hardware sets

Spacers, armour rods, dampers, suspension and dead-end assemblies removed as complete units rather than cut apart.

04

HPFF pipe cable

Paper-insulated copper cable in welded steel pipe from a retired city circuit, drained of fluid, with terminal equipment.

05

Potheads and pumping equipment

Terminal housings, pressure vessels and plant components that owners of the same design buy as spares.

06

Station bus and connections

Aluminum tube bus and jumpers from the substations at each end of the circuit.

New York

345 kV material in the New York market

345 kV work in New York is infrequent, large and slow. A reconductor or a structure replacement runs for a season and leaves a store holding part drums, spare assemblies and removed conductor; a city pipe-type retirement takes years of planning and then produces a single, very large disposal job. Neither produces a steady flow, so there is no liquid market to check a price against — which is exactly why documentation matters more here than at any other voltage.

The practical advice for a seller is to slow down. Photograph the drum tag and the cut end, note the footage, find the test records, and describe the pipe-type material as a system rather than as scrap. The difference between a considered sale and a load-out is usually decided before the first phone call.

What helps a New York lot move

  • Drum tag and footage photographed before anything is moved
  • Factory test certificates kept with the reels they belong to
  • For pipe-type: fluid type, volume and any sampling results
  • As-built drawings and terminal arrangement for a retired circuit
  • An honest note on storage and on how the material was removed
Rows of large wooden reels standing in an open yard beside a fence line
At 345 kV the reel, the tag and the test record travel together, or the material is worth weight.

Seller questions

Questions sellers ask

Why is 345 kV material so often sold as scrap?

Because it is heavy, awkward to move and usually separated from its paperwork by the time a project closes. Weight-based pricing is easy to administer and easy to accept when nobody has time to read a drum tag. The material itself has not changed; the information around it has been lost.

Can high-pressure fluid-filled cable be reused?

No. A pipe-type circuit is built as a system: the cable is dried and impregnated in factory lengths, jointed in the field under controlled conditions and then held under fluid pressure for its entire life. Reuse would mean re-impregnating and re-jointing it to the same standard, which no owner does when new cable can be bought. What carries value is the pipe, the conductor inside it and the terminal hardware.

What is running footage on a 345 kV drum?

A length marked along the conductor or recorded on the tag as the cable was manufactured, so that the remaining length can be calculated after a partial pull. It is more reliable than a hand-written note and it is one of the reasons a tagged part drum can still be sold as material.

Is 345 kV ever extruded rather than paper-insulated?

Yes, on newer work. Extruded dielectric cable at this voltage exists and has been installed in duct and direct burial, with a very heavy wall and a metallic sheath. It is a different asset from pipe-type cable: the jacket and sheath can be inspected, pulling lengths are shorter, and the reuse question is real rather than academic.

What does a buyer need for a retired city circuit?

Pipe size and run length, fluid type and volume, any sampling or test results, the terminal arrangement, and the as-found drawings. With those, a plan for draining, cutting and lifting can be priced. Without them, the first job is a site visit and a sample, and the offer has to carry that uncertainty.

City pages

Where this turns up in New York

Next step

Send the lot details

Include the storage city, how it is stored and what can reach it. If you have photographs of reel tags or jacket print, send them with the enquiry.

Send the lot details

Call or text the buying desk: 614-715-3047

saleselectricalbuyers@gmail.com

Send the lot

One desk reviews every lot that arrives.

No fee and no obligation. Nothing is bought, moved or scheduled until written lot terms are agreed.

Prefer to talk? 614-715-3047 · saleselectricalbuyers@gmail.com

Call 614-715-3047 Get a buy quote