
Transmission · Long Island and downstate
115 kV cable buyers in New York
One hundred and fifteen kilovolts is the transmission class that shaped Long Island, and its surplus arrives in two completely different forms: overhead line material on reels, and underground feeder cable cut out of duct.
- New York State
- Documented lots
- Reels and cut lengths
- Buyer review
Sell this cable
Send the construction, size and footage. Photographs can follow.
Prefer to talk? 614-715-3047 · saleselectricalbuyers@gmail.com
A 115 kV lot is either a line lot or a cable lot. Line lots are bundled conductor, spacer hardware, shield wire and OPGW, usually mixed and often untagged after storm work. Cable lots are single-conductor shielded feeder, 750 to 2500 kcmil copper, pulled out of duct and manhole. The two are valued on different facts and should never be quoted as one number.
A voltage that belongs to Long Island
Long Island's transmission network was built around 115 kV, and it still carries most of the load that moves west to east across Nassau and Suffolk. The lines run along road rights-of-way on steel poles and H-frames, through suburbs where a wider corridor was never available, which is why so much of the 115 kV work on the island is replacement in place rather than new build.
The same class appears in the lower Hudson Valley and on older upstate networks, so a 115 kV lot can come from either side of the city. The material looks similar and the economics do not: island lots carry salt exposure and storm history, upstate lots carry ice and river crossings.

Bundled conductor, OPGW and the mixed line lot
Much of the 115 kV overhead work is two sub-conductors per phase rather than one. A 795 kcmil or 1033.5 kcmil ACSR sub-conductor, run as a pair with bundle spacers at intervals, gives more capacity for the same clearance and better behavior in wind. When a line like that is rebuilt, the surplus is not one drum of conductor: it is part drums of two sizes, spacers, armour rods, dampers, suspension and dead-end assemblies, and whatever insulator strings survived the takedown.
The shield wire on top is increasingly optical. OPGW replaces the static wire with a conductor that has a stainless or aluminum tube at its core carrying 24 to 48 fibers, built to IEEE 1138 and spliced at every tension structure. It is the single most commonly undervalued item in a line lot: a part reel of OPGW looks like wire, weighs like wire, and is worth far more than wire if the fiber count, the tube type and the length are known — and worth almost nothing if the reel has been crushed or the ends left open to water.
The practical instruction for a seller is to separate by function before anyone quotes. Conductor by code name, OPGW by fiber count, hardware by assembly, insulators by type. A single price for a mixed 115 kV line lot always lands on the lowest common denominator.
- Conductor identified by code name and stranding, not by diameter alone
- OPGW with fiber count, tube construction and reel length stated
- Bundle spacers and dampers counted, since they are bought as assemblies
- Insulators separated by material — porcelain, toughened glass, composite
- Any conductor removed after storm damage flagged as such, not mixed with new stock
Duct, manhole and the underground feeder
Where the 115 kV line cannot stay overhead — through a village center, under a rail line, into a substation in a built-up area — it becomes a duct-run feeder. The cable is single-conductor, shielded, 133% insulation level, usually copper between 750 and 2500 kcmil, pulled through concrete ducts between manholes with rollers, a winch and a tension recorder.
That installation method defines the used material. Feeder cable comes out of duct in the lengths between manholes plus the slack in each splice bay, so a run that was 4,000 ft may leave as eight pieces of 400 to 600 ft with the joints cut away. The jacket is scuffed from the pull, the sheath may be dented, and the ends have been open to a manhole atmosphere for however long the removal took. Cable pulled with a tension record and capped immediately is a different asset from cable dragged out and coiled in the rain.
Older 115 kV feeders can be paper-insulated lead-covered or pipe-type, and both change the valuation completely — one is a lead and copper recovery job with an impregnant to handle, the other is a steel pipe with oil in it.
The storm and underground replacement pattern
The island's weather does the sorting for you. Nor'easters and tropical remnants bring wind-driven rain and salt fog that flash over contaminated insulators, and the restoration work that follows generates damaged conductor, bent hardware and untagged material in volume. Undergrounding programs then move sections of overhead line into duct, which produces two lots at once: the overhead conductor and hardware that came down, and the cable offcuts and part reels from the new installation.
Buyers see the same sequence repeatedly — a storm lot with no tags, followed a year or two later by a clean surplus lot from the rebuild with tags intact. The clean lot is worth several times more per pound, and it is worth the seller's time to keep the two apart rather than blending them into one roll-off.
Specification
What a buyer needs to know about this cable
Every row below changes what a lot is worth. If the reel tag is gone, the jacket print and a cut end usually answer most of it.
Missing detail is not a problem — say what is missing and the review works from photographs.
| Voltage class | 115 kV three-phase transmission, 66.4 kV to ground |
|---|---|
| Overhead conductor | ACSR or ACSS, 795 and 1033.5 kcmil in one- or two-conductor bundles |
| Shield wire | OPGW with 24 to 48 fibers, or conventional ACSR or AAAC shield wire |
| Feeder cable | Single-conductor shielded XLPE, 750 to 2500 kcmil copper, 133% insulation level |
| Installation | Concrete duct bank with manholes, direct burial, or overhead on steel poles and H-frames |
| Standards | ASTM B232 for ACSR, IEEE 1138 for OPGW, ICEA S-108-720 for the cable |
| Accessories | Bundle spacers, armour rods, vibration dampers, sheath bonding leads, link boxes |
| Condition signals | Salt bloom on hardware, water trees in old XLPE, sheath damage from pulling |
Constructions
115 kV material we review
Line lots and cable lots from the same project are different assets with different buyers.
Bundled overhead conductor
Part drums and full drums of 795 or 1033.5 kcmil ACSR and ACSS from rebuilds, with the code name still readable on the tag.
OPGW and shield wire
Optical ground wire on its original reel, with fiber count and length, plus conventional static wire from the same structures.
Duct-run feeder cable
Single-conductor shielded copper cable in manhole-length sections, cut at the joints and usually jacket-scuffed from the pull.
Storm restoration surplus
Damaged conductor, bent hardware and mixed assemblies from emergency work. Priced on salvage content unless a section is clearly sound.
Line hardware and assemblies
Bundle spacers, armour rods, dampers, dead-end and suspension assemblies, and insulator strings removed during a rebuild.
Legacy 115 kV cable
Paper-insulated lead-covered and pipe-type feeders from older underground sections, valued on metal content and handling cost.
New York
115 kV material in the New York market
Long Island is the densest concentration of 115 kV work in the state, and its contractors, utility stores and municipal systems all hold material that will never go back into the same job. Because the corridors are narrow and the load keeps growing, rebuilds happen on a rolling basis rather than in one campaign, so surplus arrives steadily instead of in a single clearance.
The market rewards sellers who can say which kind of lot they have. A line lot with tagged conductor and counted hardware sells to a line contractor; a duct-run cable lot sells on copper content, length and sheath condition. Blending them helps nobody except the buyer.
What helps a New York lot move
- Separate line material from cable before quoting
- Code name and stranding for every conductor drum
- OPGW fiber count and reel length, plus whether ends were sealed
- For feeder cable: pulling lengths, joint locations and sheath damage
- A note on salt exposure and outdoor storage, since it affects hardware and shields

Seller questions
Questions sellers ask
Do you buy OPGW separately from the conductor?
Yes, and it should be sold that way. OPGW is valued on fiber count, tube construction, reel length and the condition of the ends, none of which survive being lumped in with conductor. A sealed part reel with a known fiber count has a real reuse market; a crushed reel with water in the tube does not.
Why is 115 kV feeder cable usually in short pieces?
Because it is pulled between manholes. Duct runs are installed in sections with a splice bay at each manhole, so the cable is cut at every joint when it is removed. The remaining lengths reflect the duct geometry, typically a few hundred feet, and they are priced on usable length rather than on the original run.
Can underground 115 kV cable be reused after removal?
Only after it has been de-energised, released and tested, and the jacket and sheath have to survive inspection first. Cable that was pulled with a tension record and capped at both ends is a candidate for reuse on a lower-stress duty; cable dragged out of a wet manhole with open ends is almost always recovery material.
What does salt exposure do to 115 kV hardware?
It attacks the galvanising on steel and the aluminum on conductor and hardware, and it leaves the white bloom that tells a buyer the material sat near the shore. Aluminum-clad steel core and greased conductor survive it; plain galvanised fittings often do not, and that shows up as pitting at the contact surfaces rather than as an obvious failure.
Is a 115 kV line lot ever worth more as hardware than as conductor?
Occasionally, yes. Bundle spacers, dampers and complete dead-end assemblies are bought as sets, and a set that came off cleanly is worth more than the aluminum in it. The same applies to OPGW and to composite insulators, which have no scrap value at all but a real reuse value if they are undamaged.
Keep reading
Related pages
- High-voltage cable buyersThe parent category for transmission-class cable
- 138 kV cable buyersThe upstate sibling voltage
- 69 kV cable buyersSubtransmission below this class
- OPGW fiber buyersThe shield wire on these structures
- Transmission line cable buyersConductor, hardware and shield wire together
- ACSR conductor buyersCode names behind the bundle
City pages
Where this turns up in New York
Next step
Send the lot details
Include the storage city, how it is stored and what can reach it. If you have photographs of reel tags or jacket print, send them with the enquiry.
Send the lot
One desk reviews every lot that arrives.
Prefer to talk? 614-715-3047 · saleselectricalbuyers@gmail.com